Language

Print

Switches

Control Switches Series 8008
  • Versions
    • Control switch with 2, 3 or 4 pole
    • Load switch 3 pole + 1 auxiliary contact
  • Up to a maximum of 4 poles
  • NC contacts with positive opening, suitable for EMERGENCY STOP functions
  • Latching or spring-return versions available
ATEX / IECEx Class I (NEC 505) (NEC 506) Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
For use x x For use in x x For use in x x x x
Load and Motor Switches Series 8006/4
  • Isolator features
  • Switching capacity
  • Rated working voltage up to 690 V AC
  • Different switching arrangements available
ATEX / IECEx
Zone 0 1 2 20 21 22
For use in x x
Load and Motor Switch / Control Switch Series 8006/3
  • New Series see WebCode: 8006B
ATEX / IECEx
Zone 0 1 2 20 21 22
For use in x x
Load and Motor Switches, Load-Break Switches Series 8544
  • Innovative switch concept
  • Modular system
  • State-of-the-art contact arrangement
  • Easy and clear connection technology
  • Wiring channel for auxiliary contacts
  • Retrofittable:
    • Alligator clip
    • Auxiliary contacts
    • Ex i separation body
    • N terminal
    • PE terminal
    • Adapter plate for cable connection
  • Motor switching capacity AC-3, DC-1 and DC-23 acc. to IEC/EN 60947-3, IEC/EN 60947-4
  • Isolating characteristics according to IEC/EN 60947-4
  • Degree of protection IP2x
  • Any installation position
ATEX / IECEx
Zone 0 1 2 20 21 22
For use in x x
Load and Motor Switches, Load-Break Switches Series 8549
  • Innovative switch concept
  • State-of-the-art contact arrangement
  • Easy and clear connection technology
  • Wiring channel for auxiliary contacts
  • Retrofittable:
    • Alligator clip
    • Auxiliary contacts
    • Ex i separation body
    • N terminal
    • PE terminal
    • Adapter plate for cable connection
  • Isolating characteristics according to IEC/EN 60947-4
ATEX / IECEx
Zone 0 1 2 20 21 22
For use in x x x x
Load and Motor Switches Series 8543
  • Explosion protection to
    • IEC
    • ATEX
  • Isolator
  • Motor switching capacity
  • Rated working voltage up to 690 V
  • Rated working current 40 A, 63 A / 80 A
  • Different switching sequences available
ATEX / IECEx
Zone 0 1 2 20 21 22
For use in x x
Load and Motor Switches Series 8548
  • Isolator
  • Motor switching capacity
  • Rated working voltage up to 690 V
  • Rated working current 125 A / 160 A
  • Different switching sequences available
ATEX / IECEx
Zone 0 1 2 20 21 22
For use in x x