Horn EEx d and EEx de Series 8493 Horn EEx d and EEx de Series 8493
  • Explosion protection to
    • CENELEC
    • IEC
  • For use in
    • Zone 1 and Zone 2
    • Zone 22
  • 32 different signal sequences adjustable with internal DIP switches
  • Three different signal sequences can be selected through an external switch with a given DIP switch setting
  • Three PFEER signals
    • "General alarm"
    • "Toxic gas alarm"
    • "Prepare to abandon platform"
  • Volume control max. 117 dB(A)
  • Robust aluminium enclosure with horn in ABS
  • Synchronized tone sequence of parallel operated devices by quartz-controlled oscillator
  • Option: speaker module, programmable
Horn for EEx i Circuits Series 8492 Horn for EEx i Circuits Series 8492
  • Explosion protection
    • CENELEC
    • IEC
  • For use in
    • Zone 0
    • Zone 1 and Zone 2
  • 49 different signal sequences adjustable with internal DIP switches
  • Three different signal sequences can be selected through an external switch with a given DIP switch setting
  • Three PFEER signals
    • General alarm
    • Toxic gas alarm
    • Prepare to abandon platform
  • Volume adjustable
  • Robust plastic enclosure (ABS)
  • Synchronized tone sequence of parallel operated devices by quartz-controlled oscillator
  • Option: speaker module, programmable
Horn Series 8491 Horn Series 8491
  • Explosion protection to
    • CENELEC
    • IEC
  • Fixed signal tone
  • Max. 105 dB (A) at 1 m distance

Horn Version 8491/1

  • With flexible lead
  • For use in
    • Zone 1 and Zone 2

Horn Version 8491/2

  • With connection chamber and cable gland
  • For use in
    • Zone 1 and Zone 2
    • Zone 21 and Zone 22
Flashing Beacon and Continuous Beacon Series 6161 Flashing Beacon and Continuous Beacon Series 6161
  • Explosion protection to
    • CENELEC
    • EC
  • For use in
    • Zone 1 and Zone 2
    • Zone 21 and Zone 22
  • Saltwater-proof aluminium enclosure with polycarbonate hood
  • Flashing frequency 1 Hz
  • Integrated Ex e service compartment
  • Available in clear, signal yellow, red, blue, green and orange
  • Flashing energy 5 Joules
  • Continuous beacon in LED technology
Signal Beacon Series 6162 Signal Beacon Series 6162
  • Explosion protection to
    • CENELEC
    • IEC
  • For use in
    • Zone 1 and Zone 2
    • Zone 21 and Zone 22
  • Versions
    • rotating mirror beacon
    • rotating beacon
    • beacon with double flash (14 J)
    • flashing beacon (15 J)
  • Saltwater-proof aluminium enclosure with glass hood
  • Integrated Ex e service compartment
  • Glass hood available in clear, signal yellow, red, blue and orange
  • Halogen lamp 20 W, 35 W
Navigation Light Series TEF 2840 C Navigation Light Series TEF 2840 C
  • Navigation lights for all vessels < 50 metres in length
  • Integrated terminal box
  • 24 V DC light source for extremely prolonged lifetime
  • Desinged for use in arctic and tropical waters
  • Resistant to vibrations
  • Lens of through-coloured glass, - no de-colouration throughout the lifetime of the lantern
  • 20 years waranty on lantern
  • Small dimensions - low weight
  • For use in
    • Marine application
Navigation Light Series TEF 2850 Navigation Light Series TEF 2850
  • Vessels 20 - 50 m in length, certificated issued, bassed upon the use of 35 cd (55 W) latern lamp
  • Integrated terminal box
  • Hinged on top - enabling quick replacement of light source
  • All round lanterns are delivered with mounting bracket for 2" pipe
  • Designed for use in arctic and tropical waters
  • Resistant to vibrations
  • Lens of through-coloured glass, no de-colouration throughout the lifetime of the lantern
Navigation Light Series TEF 2870 Navigation Light Series TEF 2870
  • Navigation lights for all vessels 20-50 meter and < 50 meters in length
  • As special, the lanterns may be delivered as Ex nR lantern, to be used in Ex Zone 2
  • Integrated terminal box - no need for extra connection box
  • 24 V DC light source for extremely prolonged lifetime
  • Designed for use in both arctic and tropical waters
  • Resistant to vibrations
  • Lens of through-coloured glass, - no de-colouration throughout the lifetime of the lantern
  • 20 years warranty on lantern
  • small dimensions - low weight
  • For use in
    • Marine application
Navigation Light for Vessels 7-20 Meters Series TEF 2898 Navigation Light for Vessels 7-20 Meters Series TEF 2898
  • Applications
    • Navigation lights for vessels 7-20 meters
    • Signal lights
  • For use in
    • Marine application
    • Safe area
  • Connect to max. 12/24 V AC/DC voltage for extremely long light bulb lifetime
  • Extremely durable to mechnical deterioration
  • Designed for use in artic and tropical waters
  • Small dimensions - low weight
  • Resistant to vibrations
  • Lens of through-coloured glass, no de-colouration throughout the lifetime of the lantern
  • The lens can easily be cleaned
  • Access to bulb from top - enabling quick replacement of light source
  • Can be used against all types of metal by using isolation washers
  • Direct connection in lantern
Signal Beacon Series TEF 2940 Signal Beacon Series TEF 2940
  • Docks, Pipes, Bridge navigation light
  • Integrated terminal box - no need for extra connection box
  • Designed for use in both arctic and tropical waters
  • Lens of through-coloured glass, no de-colouration throughout the lifetime of the lantern
  • Access to bulb from top - enabling quick replacement of light source
  • Can be mounted against all types of metal by using attached isolation washers
  • 20 years waranty on lantern
Signal beacon Series TEF 2440 Signal beacon Series TEF 2440
  • Application
    • Deck lighting
    • Signal lighting
    • Obstacle marking
  • For use in
    • Zone 2
    • Safe Area
  • Rugged construction
  • Easy to install and maintain
  • Proven ingress protection
  • Long lamp life compact fluorescent tube
  • Versatility offering variable mounting positions
  • Optional internal lamp reflector
  • Wide range of coloured globes available
  • Short ignition time at low temperatures
  • Resistant to vibrations
Obstruction Light Series TEF 2441 Obstruction Light Series TEF 2441
  • Applications
    • Signal lighting
    • Obstacle marking
  • For use in
    • Safe area
  • Rugged design
  • Easy to install and maintain
  • Proven ingress protection
  • Long lamp life using compact fluorescent tube, up to 9000 hours
  • Automatic lamp change-over when lamp failure
  • Can be supplied with potential free alarm contact
  • Short ignition time at low temperature
  • Resistant to vibrations
  • Expected maintenance free for up to 18 000 hours
Illuminated Windsock Series TEF 9967 Illuminated Windsock Series TEF 9967
  • Wind indication on:
    • Helicopter landing areas
    • Airports
    • Bridges
    • Highways
  • For use in
    • Zones 1 & 2
    • Safe area
  • Rugged and solid construction
  • 4 certified luminaires mounted in SS316L reflector with junction box
  • Easy to install and maintain
  • 1 or 2 obstruction lights on top
  • To be mounted on top of 2" tube
  • Cable for power supply through 2" tube
  • Resistant to vibrations
  • Bearing for rotating the wind cone encapsulated in solid brass housing
Traffic Light Series 6091/2 Traffic Light Series 6091/2
  • For use in
    • Zone 1 and Zone 2
    • Zone 22
  • Available with 1, 2 or 3 lenses
  • Lenses in
    • red
    • signal yellow
    • green
    • blue
    • clear
  • Incandescent lamps max. 60 W, 230 V
  • 4 m long connection lead
Grounding Systems / Grounding Monitoring Device Series UZCL Grounding Systems / Grounding Monitoring Device Series UZCL
  • Monitored electrostatic grounding of road tankers and tank wagons during the loading and unloading of flammable liquids
  • Safe vertification of the connected object-distinction between road tanker and other objects like loading platform
  • For use in Zone 1 and Zone 2
  • Robust design
  • Easy installation and operation
  • Two potential free contacts (Ex e) for signalisation to the control system and control of alarm devices
Grounding System / Grounding Monitoring Device Series 8146/5075 Grounding System / Grounding Monitoring Device Series 8146/5075
  • Monitored electrostatic grounding of tank container and drums during the loading and unloading of flammable liquids
  • For use in Zone 1 and Zone 2
  • Robust design
  • Easy installation and operation
  • Potential free contact for signalisation to the control system and control of alarm devices