Horn EEx d and EEx de Series 8493
- Explosion protection to
- For use in
- Zone 1 and Zone 2
- Zone 22
- 32 different signal sequences adjustable with internal DIP switches
- Three different signal sequences can be selected through an external switch with a given DIP switch setting
- Three PFEER signals
- "General alarm"
- "Toxic gas alarm"
- "Prepare to abandon platform"
- Volume control max. 117 dB(A)
- Robust aluminium enclosure with horn in ABS
- Synchronized tone sequence of parallel operated devices by quartz-controlled oscillator
- Option: speaker module, programmable
|
 |
Horn for EEx i Circuits Series 8492
- Explosion protection
- For use in
- 49 different signal sequences adjustable with internal DIP switches
- Three different signal sequences can be selected through an external switch with a given DIP switch setting
- Three PFEER signals
- General alarm
- Toxic gas alarm
- Prepare to abandon platform
- Volume adjustable
- Robust plastic enclosure (ABS)
- Synchronized tone sequence of parallel operated devices by quartz-controlled oscillator
- Option: speaker module, programmable
|
 |
Horn Series 8491
- Explosion protection to
- Fixed signal tone
- Max. 105 dB (A) at 1 m distance
Horn Version 8491/1 - With flexible lead
- For use in
Horn Version 8491/2 - With connection chamber and cable gland
- For use in
- Zone 1 and Zone 2
- Zone 21 and Zone 22
|
 |
Flashing Beacon and Continuous Beacon Series 6161
- Explosion protection to
- For use in
- Zone 1 and Zone 2
- Zone 21 and Zone 22
- Saltwater-proof aluminium enclosure with polycarbonate hood
- Flashing frequency 1 Hz
- Integrated Ex e service compartment
- Available in clear, signal yellow, red, blue, green and orange
- Flashing energy 5 Joules
- Continuous beacon in LED technology
|
 |
Signal Beacon Series 6162
- Explosion protection to
- For use in
- Zone 1 and Zone 2
- Zone 21 and Zone 22
- Versions
- rotating mirror beacon
- rotating beacon
- beacon with double flash (14 J)
- flashing beacon (15 J)
- Saltwater-proof aluminium enclosure with glass hood
- Integrated Ex e service compartment
- Glass hood available in clear, signal yellow, red, blue and orange
- Halogen lamp 20 W, 35 W
|
 |
Navigation Light Series TEF 2840 C
- Navigation lights for all vessels < 50 metres in length
- Integrated terminal box
- 24 V DC light source for extremely prolonged lifetime
- Desinged for use in arctic and tropical waters
- Resistant to vibrations
- Lens of through-coloured glass, - no de-colouration throughout the lifetime of the lantern
- 20 years waranty on lantern
- Small dimensions - low weight
- For use in
|
 |
Navigation Light Series TEF 2850
- Vessels 20 - 50 m in length, certificated issued, bassed upon the use of 35 cd (55 W) latern lamp
- Integrated terminal box
- Hinged on top - enabling quick replacement of light source
- All round lanterns are delivered with mounting bracket for 2" pipe
- Designed for use in arctic and tropical waters
- Resistant to vibrations
- Lens of through-coloured glass, no de-colouration throughout the lifetime of the lantern
|
 |
Navigation Light Series TEF 2870
- Navigation lights for all vessels 20-50 meter and < 50 meters in length
- As special, the lanterns may be delivered as Ex nR lantern, to be used in Ex Zone 2
- Integrated terminal box - no need for extra connection box
- 24 V DC light source for extremely prolonged lifetime
- Designed for use in both arctic and tropical waters
- Resistant to vibrations
- Lens of through-coloured glass, - no de-colouration throughout the lifetime of the lantern
- 20 years warranty on lantern
- small dimensions - low weight
- For use in
|
 |
Navigation Light for Vessels 7-20 Meters Series TEF 2898
- Applications
- Navigation lights for vessels 7-20 meters
- Signal lights
- For use in
- Marine application
- Safe area
- Connect to max. 12/24 V AC/DC voltage for extremely long light bulb lifetime
- Extremely durable to mechnical deterioration
- Designed for use in artic and tropical waters
- Small dimensions - low weight
- Resistant to vibrations
- Lens of through-coloured glass, no de-colouration throughout the lifetime of the lantern
- The lens can easily be cleaned
- Access to bulb from top - enabling quick replacement of light source
- Can be used against all types of metal by using isolation washers
- Direct connection in lantern
|
 |
Signal Beacon Series TEF 2940
- Docks, Pipes, Bridge navigation light
- Integrated terminal box - no need for extra connection box
- Designed for use in both arctic and tropical waters
- Lens of through-coloured glass, no de-colouration throughout the lifetime of the lantern
- Access to bulb from top - enabling quick replacement of light source
- Can be mounted against all types of metal by using attached isolation washers
- 20 years waranty on lantern
|
 |
Signal beacon Series TEF 2440
- Application
- Deck lighting
- Signal lighting
- Obstacle marking
- For use in
- Rugged construction
- Easy to install and maintain
- Proven ingress protection
- Long lamp life compact fluorescent tube
- Versatility offering variable mounting positions
- Optional internal lamp reflector
- Wide range of coloured globes available
- Short ignition time at low temperatures
- Resistant to vibrations
|
 |
Obstruction Light Series TEF 2441
- Applications
- Signal lighting
- Obstacle marking
- For use in
- Rugged design
- Easy to install and maintain
- Proven ingress protection
- Long lamp life using compact fluorescent tube, up to 9000 hours
- Automatic lamp change-over when lamp failure
- Can be supplied with potential free alarm contact
- Short ignition time at low temperature
- Resistant to vibrations
- Expected maintenance free for up to 18 000 hours
|
 |
Illuminated Windsock Series TEF 9967
- Wind indication on:
- Helicopter landing areas
- Airports
- Bridges
- Highways
- For use in
- Rugged and solid construction
- 4 certified luminaires mounted in SS316L reflector with junction box
- Easy to install and maintain
- 1 or 2 obstruction lights on top
- To be mounted on top of 2" tube
- Cable for power supply through 2" tube
- Resistant to vibrations
- Bearing for rotating the wind cone encapsulated in solid brass housing
|
 |
Traffic Light Series 6091/2
- For use in
- Zone 1 and Zone 2
- Zone 22
- Available with 1, 2 or 3 lenses
- Lenses in
- red
- signal yellow
- green
- blue
- clear
- Incandescent lamps max. 60 W, 230 V
- 4 m long connection lead
|
 |
Grounding Systems / Grounding Monitoring Device Series UZCL
- Monitored electrostatic grounding of road tankers and tank wagons during the loading and unloading of flammable liquids
- Safe vertification of the connected object-distinction between road tanker and other objects like loading platform
- For use in Zone 1 and Zone 2
- Robust design
- Easy installation and operation
- Two potential free contacts (Ex e) for signalisation to the control system and control of alarm devices
|
 |
Grounding System / Grounding Monitoring Device Series 8146/5075
- Monitored electrostatic grounding of tank container and drums during the loading and unloading of flammable liquids
- For use in Zone 1 and Zone 2
- Robust design
- Easy installation and operation
- Potential free contact for signalisation to the control system and control of alarm devices
|