STAHL LOGO

Home

Print

Temperature

Temperature Transmitter with Output 0/4 ... 20 mA, without Limit Value Contact (Field Circuit Non-Ex i) Type 9182/.0-51-61
Temperature Transmitter with Output 0/4 ... 20 mA, without Limit Value Contact (Field Circuit Non-Ex i) Type 9182/.0-51-61
  • One unit for nearly all temperature sensors indivdually configurable
  • 1 and 2 channels
  • Signal duplication possible
  • Galvanic isolation between input, output, power supply and configuration interface
  • Open-circuit and short-circuit monitoring and messaging (can be switched off)
  • Simple configuration with PC or DIP-switches
  • Installation possible in Zone 2

 

Zones

0

1

2

20

21

22

Ex i
interfaces

Installation in

X

X

Temperature Transmitter with Output 0/4 ... 20 mA, without Limit Value Contact, SIL (Field Circuit Non-Ex i) Type 9182/10-5.-63
Temperature Transmitter with Output 0/4 ... 20 mA, without Limit Value Contact, SIL (Field Circuit Non-Ex i) Type 9182/10-5.-63
  • One unit for nearly all temperature sensors indivdually configurable
  • 1 channel
  • Galvanic isolation between input, output, power supply and configuration interface
  • Open-circuit and short-circuit monitoring and messaging
  • Simple configuration with PC
  • Installation possible in Zone 2
  • Can be used up to SIL 2 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i
interfaces

Installation in

X

X

Temperature Transmitter with Output 0/4 ... 20 mA and Limit Value Contact (Field Circuit Non-Ex i) Type 9182/10-51-62
Temperature Transmitter with Output 0/4 ... 20 mA and Limit Value Contact (Field Circuit Non-Ex i) Type 9182/10-51-62
  • One unit for nearly all temperature sensors indivdually configurable
  • 1 channel
  • Galvanic isolation between input, output, power supply and configuration interface
  • Open-circuit and short-circuit monitoring and messaging (can be switched off)
  • Simple configuration with PC
  • Installation possible in Zone 2

 

Zones

0

1

2

20

21

22

Ex i
interfaces

Installation in

X

X

Temperature Transmitter with Output 0/4  ... 20 mA and Limit Value Contact, SIL 2 (Field Circuit Non-Ex i) Type 9182/10-51-64
Temperature Transmitter with Output 0/4 ... 20 mA and Limit Value Contact, SIL 2 (Field Circuit Non-Ex i) Type 9182/10-51-64
  • One unit for nearly all temperature sensors indivdually configurable
  • 1 channel
  • Galvanic isolation between input, output, power supply and configuration interface
  • Open-circuit and short-circuit monitoring and messaging (can be switched off)
  • Simple configuration with PC
  • Installation possible in Zone 2
  • Can be used up to SIL 2 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i
interfaces

Installation in

X

X

 

10648E00

10648E00