Print
Emergency Light Fittings
 |
Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22)
- Version
- C-LUX 6108 for Zone 1 and Zone 2, Zone 21 and Zone 22
- C-LUX 6508 for Zone 2 and Zone 22
- With electronic ballast and integrated emergency light electronics
- Operating modes
- non-maintained operation
- non-maintained operation with switchable emergency light blocking
- With or without continous operating test
- For fluorescent lamps 8 W,
16 mm, for two-pin holder G5 - Suitable for wall and ceiling mounting
- Can be fitted to order with emergency exit signs
- Central locking
- Enclosure in polyester resin; cover in polycarbonate
|
 |
Compact Sheet-Steel Emergency Light Fitting Series 6118 (Zone 1) Series 6518 (Zones 2, 21, 22)
- Versions
- 6118 for use zone 1
- 6518 for use in zones 2, 21 and 22
- Electronic ballast and integral emergency light unit
- For continuous emergency operation 1,5 h
- Operation modes
- Maintained operation
- Maintained operation with switchable emergency light blocking
- Non-maintained operation
- With weekly functional test
- With automatic emergency light duration test
- With discharge protection and charging voltage limiting
- With intelligent charging technology
- For fluorescent lamps 8 W
- Central lock
- Housing in powder-coated sheet-steel or in stainless steel
- Glass cover can be fitted with emergency exit signs to order
|
 |
Emergency Light Fittings for Fluorescent Lamps Series EXLUX 6008 (Zone 1) EXLUX 6408 (Zones 2, 21, 22)
- As pendant or pole-mounting fittings
- With electronic ballast with integrated emergency light unit
- For two-pin fluorescent lamps
- 2 lamp versions:
18 W and 36 W - Central locking
- All-pole disconnection via N/C switch when opening light fitting or battery enclosure
- Enclosure in polyester resin
- Cover in polycarbonate
- In maintained operation or non-maintained operation with switchable emergency light blocking
- Operating test, weekly
- Emergency light duration test (at intervalls of 6 months)
|
 |
Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608
- For use in
- Zone 2
- Zone 21 and Zone 22
- For fluorescent lamps 2 x 18 W and 2 x 36 W
- With electronic ballast and integrated microprocessor controlled emergency lighting electronics
- For emergency light operation periods of 1.5 or 3 hrs
- Operating types
- continuous circuit
- continuous circuit with switchable emergency light blocking mechanism
- Intelligent charging method
- Battery case which can be opened separately for easy change of batteries by means of plug-type contacts
- Housing made of glass-fibre reinforced polyester resin, diffuser cover made of shockresistant polycarbonate
- Housing sealed with quick-action fasteners
|
 |
Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 Economy
- For use in
- For fluorescent lamps 2 x 18 W and 2 x 36 W
- With electronic ballast and integrated emergency lighting electronics
- For emergency light operation periods of 1.5 hrs
- Intelligent charging method
- Housing made of glass-fibre reinforced polyester resin, diffuser cover made of shockresistant polycarbonate
- Housing sealed with quick-action fasteners
|
 |
Sheet-Steel Emergency Light Fitting Series 6018 (Zone 1) Series 6418 (Zones 2, 21 & 22)
- Versions
- Series 6018 for use in Zone 1
- Series 6418 for use in Zone 2, 21 & 22
- Electronic ballast with integral emergency light unit
- Emergency light operating duration 1.5 h or 3 h
- Operation modes
- Maintained operation or
- Maintained operation with switchable emergency light blocking
- With weekly function test
- With or without emergency light duration test (adjustable in the light fitting)
- With discharge protection and charging voltage limiting
- With intelligent charging technology
- For fluorescent lamps 18 W and 36 W
- Central lock
- Enclosure in powder-coated sheet-steel or stainless steel
- Battery enclosure is to open separately, easy battery exchange via plug contacts
|
|
|