Compact Emergency Light Fittings Series C-LUX 6108 / 6508
Compact Emergency Light Fittings Series C-LUX 6108 / 6508
  • Operating modes
    • non-maintained operation
    • non-maintained operation with switchable emergency light blocking
  • With continous operating test
  • For fluorescent lamps 8 W, 16 mm, for two-pin holder G5
  • Suitable for wall and ceiling mounting
  • Can be fitted to order with emergency exit signs
  • Central locking
ATEX / GOST*
Zone 0 1 2 20 21 22
6108: For use in x x x x
6508: For use in x x x
Compact Sheet-steel Emergency Light Fitting Series 6118
Compact Sheet-steel Emergency Light Fitting Series 6118
  • Electronic ballast with integrated emergency light unit for continuous operation
  • Tests
    • With weekly functional test
    • With automatic emergency light duration test
  • With discharge protection and charging voltage limitation
  • For fluorescent lamps 8 W
  • Central locking
  • Enclosure in powder-coated sheet steel or stainless steel
ATEX
Zone 0 1 2 20 21 22
For use in x x
Emergency Light Fitting for Fluorescent Lamps Series 6009
Emergency Light Fitting for Fluorescent Lamps Series 6009
  • As wall, ceiling and pendant light fitting or pole mounted light fitting
  • Version with 2 lamps: 18 W and 36 W
  • Central locking
  • All-pole disconnection via N/C switch when opening light fitting or battery enclosure
  • Weekly functional test
  • Light duration test of the emergency lighting once a year
ATEX / IECEx
Zone 0 1 2 20 21 22
For use in x x x x
Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408
Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408
  • As pendant light fitting or side entry lamp
  • Version with 2 lamps: 18 W and 36 W
  • Central locking
  • Weekly functional test
  • Light duration test of the emergency lighting once a year
ATEX / IECEx Class I (NEC 505) (NEC 506) Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
EXLUX 6008
For use in:
x x x EXLUX 6008
For use in:
x x EXLUX 6008
For use in:
x x x x x
EXLUX 6408
For use in:
x*) x*) x*) EXLUX 6408
For use in:
x EXLUX 6408
For use in:
x x x x x
Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608
Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608
  • For fluorescent lamps 2 x 18 W and 2 x 36 W
  • For emergency light operation periods of 1.5 or 3 hrs
  • During emergency time: If emergency lamp broken changing to the other lamp
  • Battery case which can be opened separately for easy change of batteries by means of plug-type contacts
  • Enclosure closed by means of quick-action locks
ATEX Class I (NEC 505) (NEC 506) Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
For use in x x x For use in x For use in x x x x x
Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy
Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy
  • For fluorescent lamps 2 x 18 W and 2 x 36 W
  • Electronic ballast with integrated emergency light electronics
  • Battery is integrated in the lamp enclosure
  • For emergency light mode 1.5 h
  • Intelligent charging technology
  • Enclosures in glass fibre reinforced polyester resin, lamp cover in shock-resistant polycarbonate
  • Enclosure closed by means of quick-action locks
ATEX / IECEx / GOST
Zone 0 1 2 20 21 22
For use in x x
Sheet Steel Emergency Light Fitting Series 6018
Sheet Steel Emergency Light Fitting Series 6018
  • For an operating duration of 1.5 or 3 h
  • Operating modes
    • Continuous operation
    • Continuous operation with switchable emergency light blocking
  • Weekly functional test
  • Total discharge protection and charging voltage limitation
  • Enclosure in powder-coated steel sheet or stainless steel
ATEX
Zone 0 1 2 20 21 22
For use in x x