Language

Print

Emergency Lighting Technology

Emergency Lighting Technology Group and Central Battery Installations
Emergency Lighting Technology Group and Central Battery Installations
  • 19’’ Version on pivoting frame (WFZB)
  • Free programmation
  • High operational safety
  • Electronic test log
  • Network-capable
  • ILS-Technology
Emergency luminaire for fluorescent lamps for central battery units Series EXLUX 6006
Emergency luminaire for fluorescent lamps for central battery units Series EXLUX 6006
  • As wall, ceiling and pendant light fitting or pole mounted light fitting
  • Version with 2 lamps: 36 W and 58 W
  • Central locking
  • All-pole disconnection by means of an N/C switch when the lamp is opened
  • with address module for luminaire control and monitoring
ATEX / IECEx
Zone 0 1 2 20 21 22
For use in: x x x x
Emergency Light Fitting for Fluorescent Lamps Series 6009
Emergency Light Fitting for Fluorescent Lamps Series 6009
  • As wall, ceiling and pendant light fitting or pole mounted light fitting
  • Version with 2 lamps: 18 W and 36 W
  • Central locking
  • All-pole disconnection via N/C switch when opening light fitting or battery enclosure
  • Weekly functional test
  • Light duration test of the emergency lighting once a year
ATEX / IECEx
Zone 0 1 2 20 21 22
For use in x x x x
Emergency Luminaire for Fluorescent Lamps Series EXLUX 6409
Emergency Luminaire for Fluorescent Lamps Series EXLUX 6409
  • As wall, ceiling and pendant light fitting or pole mounted light fitting
  • Version with 2 lamps: 18 W and 36 W
  • Central locking
  • Disconnecting the battery circuit when opening the luminaire or the battery box
  • Weekly functional test
  • Light duration test of the emergency lighting once a year
ATEX / IECEx
Zone 0 1 2 20 21 22
For use in: x x x
Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608
Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608
  • For fluorescent lamps 2 x 18 W and 2 x 36 W
  • For emergency light operation periods of 1.5 or 3 hrs
  • During emergency time: If emergency lamp broken changing to the other lamp
  • Battery case which can be opened separately for easy change of batteries by means of plug-type contacts
  • Enclosure closed by means of quick-action locks
ATEX Class I (NEC 505) (NEC 506) Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
For use in x x x For use in x For use in x x x x x
Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 Economy
Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 Economy
  • For use in
    • Zone 2
    • Zonen 21 & 22
  • For fluorescent lamps 2 x 18 W and 2 x 36 W
  • With electronic ballast and integrated emergency lighting electronics
  • For emergency light operation periods of 1.5 hrs
  • Intelligent charging method
  • Housing made of glass-fibre reinforced polyester resin, diffuser cover made of shockresistant polycarbonate
  • Housing sealed with quick-action fasteners
Zones 2, 21 & 22
Sheet Steel Emergency Light Fitting Series 6018
Sheet Steel Emergency Light Fitting Series 6018
  • For an operating duration of 1.5 or 3 h
  • Operating modes
    • Continuous operation
    • Continuous operation with switchable emergency light blocking
  • Weekly functional test
  • Total discharge protection and charging voltage limitation
  • Enclosure in powder-coated steel sheet or stainless steel
ATEX
Zone 0 1 2 20 21 22
For use in x x
Compact Sheet-steel Emergency Light Fitting Series 6118/1
Compact Sheet-steel Emergency Light Fitting Series 6118/1
  • Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic testing.
  • Tests
    • with weekly functional test
    • with annual rated operating time test
  • With discharge protection and charging voltage limitation
  • For fluorescent lamps 8 W
  • Central locking
  • Powder-coated steel or stainless steel
ATEX / IECEx
Zone 0 1 2 20 21 22
6118/1: for use in x x x x