Language

Print

Analog Input Modules

Analog Universal Module HART for Zone 1 Series 9468/32
Analog Universal Module HART for Zone 1 Series 9468/32
  • 8 channels can be adjusted individually as analog inputs or outputs
  • Intrinsically safe inputs/outputs Ex ia
  • For 0/4…20 mA + HART signals
  • Line fault monitoring and LED display per channel
  • Diagnostics based on NE107
  • Module can be replaced in the hazardous area under power (hot swap)
ATEX / IECEx
Zone 0 1 2 20 21 22
Ex interface x x x x x x
Installation in x x x x
Analog Universal Module HART for Zone 2 Series 9468/33
Analog Universal Module HART for Zone 2 Series 9468/33
  • 8 channels can be adjusted individually as analog inputs or outputs
  • Intrinsically safe inputs/outputs Ex ia
  • For 0/4…20 mA + HART signals
  • Line fault monitoring per channel
  • Diagnostics based on NE107
  • Module can be replaced in the hazardous area under power (hot swap)
ATEX / IECEx
Zone 0 1 2 20 21 22
Ex interface x x x x x x
Installation in x x x
Analog Input Module Ex i / I.S. Inputs, 8 Channels for Zone 1 / Div. 1 Series 9460
Analog Input Module Ex i / I.S. Inputs, 8 Channels for Zone 1 / Div. 1 Series 9460
  • 8 channels for 2-wire transmitters and 4 channels for 3- and 4-wire transmitters and current sources
  • Intrinsically safe inputs Ex ia IIC
  • Galvanic separation between the inputs and the system
  • Open-circuit and short-circuit monitoring for each field circuit
  • Module can be replaced in operation (hot swap)
  • New version: Type 9468/32
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex interface x x x x x x Ex interface x x x x x x Ex interface x x x x x x
Installation in x x x*) x*) Installation in x x x*) x*) Installation in x x x*) x*) x*) x*)
Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/12-08-11
Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/12-08-11
  • 8 channels for 2-wire HART transmitters
  • Intrinsically safe inputs Ex ia IIC
  • Galvanic separation between inputs and system
  • Open-circuit and short-circuit monitoring for each field circuit
  • Module can be replaced in operation (hot swap)
  • New version: Type 9468/32
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex interface x x x x x x Ex interface x x x x x x Ex interface x x x x x x
Installation in x x x*) x*) Installation in x x x*) x*) Installation in x x x*) x*) x*) x*)
Analog Input Module HART Ex i / I.S. Inputs, 4 + 4 Channels Type 9461/12-08-21
Analog Input Module HART Ex i / I.S. Inputs, 4 + 4 Channels Type 9461/12-08-21
  • 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters
  • Intrinsically safe inputs Ex ia IIC
  • Galvanic separation between inputs and system
  • Open-circuit and short-circuit monitoring for each field circuit
  • Module can be replaced in operation (hot swap)
  • New version: Type 9468/32
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex interface x x x x x x Ex interface x x x x x x Ex interface x x x x x x
Installation in x x x*) x*) Installation in x x x*) x*) Installation in x x x*) x*) x*) x*)
Analog Input Module HART Ex n / NI Inputs, 8 Channels Series 9461/15
Analog Input Module HART Ex n / NI Inputs, 8 Channels Series 9461/15
  • 8 channels for 2-wire HART transmitters
  • Inputs for Ex nL, Ex nA and Nonincendive
  • Galvanic separation between inputs and system
  • Open-circuit and short-circuit monitoring for each field circuit
  • Module can be replaced in operation (hot swap)
ATEX NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex interface x x Ex interface x x Ex interface x x x
Installation in x x*) Installation in x x*) Installation in x x*) x*)
Safety Analog Input Module HART Ex i / I.S. Inputs, 8/6 Channels Series 9462
Safety Analog Input Module HART Ex i / I.S. Inputs, 8/6 Channels Series 9462
  • For all applications up to SIL 2 via PROFIsafe protocol (V1 or V2)
  • For SIL type 2-wire HART transmitters
  • 6 or 8 channels
  • Intrinsically safe inputs Ex ia IIC
  • Galvanic separation between inputs and system
  • Open-circuit and short-circuit monitoring for each field circuit
  • Status LEDs for RUN and ERROR, display for text messages
ATEX
Zone 0 1 2 20 21 22
Ex interface x x x x x x
Installation in x x x*) x*)