STAHL Logo

Home

Print

Analog Input Modules

Analog Input Module Type 9460 Analog Input Module Type 9460
  • 8 channels for 2-wire transmitters and 4 channels for 3- and 4-wire transmitters and current sources
  • Intrinsically safe Ex ia IIC inputs
  • Galvanic isolation between inputs and system
  • Open-circuit and short-circuit monitoring for each field circuit
  • Connection of the field cables with plug-in terminals
  • Module can be replaced while powered up (hot swap)
  • Installation in
    • Zone 1 / Division 1 and Zone 2 / Division 2
    • Zone 21 und Zone 22

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

X

X

X

X

Analog Input Module HART Ex i Inputs, 8 Channels Type 9461/12-08-11 Analog Input Module HART Ex i Inputs, 8 Channels Type 9461/12-08-11
  • 8 channels for 2-wire HART transmitter
  • Intrinsically safe Ex ia IIC
  • Galvanic isolation between inputs and system
  • Open-circuit and short-circuit monitoring for each field circuit
  • Connection of the field cables with plug-in terminals
  • Modules can be replaced while powered up (hot swap)

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

X

X

X

X

Analog Input Module HART, Ex i Inputs, 4 + 4 Channels Type 9461/12-08-21 Analog Input Module HART, Ex i Inputs, 4 + 4 Channels Type 9461/12-08-21
  • 4 channels for 2-wire HART transmitter and 4 channels for 4-wire HART transmitter
  • Intrinsically safe Ex ia IIC inputs
  • Galvanic isolation between inputs and system
  • Open-circuit and short-circuit monitoring for each field circuit
  • Connection of the field cables with plug-in terminals
  • Modules can be replaced while powered up (hot swap)

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

X

X

X

X

Analog Input Module HART Non-Ex i, 8 Channels Type 9461/15 Analog Input Module HART Non-Ex i, 8 Channels Type 9461/15
  • 8 channels for 2-wire HART transmitter
  • Inputs for Ex nL and Ex nA
  • Galvanic isolation between inputs and system
  • Open-circuit and short-circuit monitoring for each field circuit
  • Connection of the field cables with plug-in terminals
  • Modules can be replaced while powered up (hot swap)

Zones

0

1

2

20

21

22

Ex-interfaces

X

X

Installation in

X

X

Safety-Analog Input Module HART Type 9462/12-0.-11 Safety-Analog Input Module HART Type 9462/12-0.-11
  • For all applications up to SIL 2 via PROFIsafe protocol (V1 or V2)
  • For SIL type 2-wire HART transmitters
  • 6 or 8 channels
  • Intrinsically safe Ex ia IIC inputs
  • Galvanic isolation between inputs and system
  • Wire break and short circuit monitoring for each field current circuit
  • Status LEDs for RUN and ERROR, display screen for messages in plain language
  • Installation in
    • Zone 1 / Division 1
    • Zone 2 / Division 2
    • Zone 21 and Zone 22

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

X

X

X

X

 Data Sheets
 Downloads